The insertion force test machine is used in the insertion and extraction force tests of various kinds of connectors. It is equipped with an automatic acropetal device and a special fixture for all kinds of connectors, it can ensure accurate insertion and extraction force results. The machine adopts the Windows program, which is easy to operate and can automatically store test data (such as load-stroke curve, load life die-away curve, and test results) and all test conditions. The machine also adopts high-precision load cell measurement and servo motor drive, which ensures accurate insertion and extraction force results. It is an essential detecting instrument in the development research and quality inspection of connector manufacturers and finished product manufacturers.
Product Specification
MODEL | XB-OTS-1220S |
---|---|
Capacity (Optional) | 5kgf,10kgf, 20kgf, 50kgf,100kgf |
Unit (Switchable) | kgf, N, Lb, gf |
Load Accuracy | ±0.5% |
Load Least Display | 0.01kgf or 0.01gf |
Test Stroke | 0~150mm |
Stroke Least Display | 0.001mm |
Effective Width | 200,400mm (optional) |
Test speed | 0~200mm/min or 600mm/min |
Speed Accuracy | ±0.5% |
Motor | Panasonic servo motor |
Dimension (WxDxH) | 360x270x950mm |
Insertion Force Test Machine Features
- Use touch screen control to operate and intuitively.
- Independent controller to control the motor so that the trip is accurate up to 0.01mm. This is another mechanical control stroke or photoelectric control stroke. Simple plug test machines can not be compared.
- Design is load protection. When the upper and lower limits were set, the test machine stopped the action to prevent the sensor from automatically crashing.
- A single function can only do the plug-in test. The stroke is mechanical control (adjust the deflection wheel or the electrical switch). Travel accuracy can not meet the connector test requirements.
- The test procedure is quite simple. When the customer misuses the upper and lower jigs hit together, the program can not stop the test machine from working. This will do significant damage to the sensor.
- Compared with the horizontal plug force, an automatic heart device can be equipped. The test is not inserted partially. It is a connector manufacturer of considerable practical utility for the plug test machine.
Applications
Connector whole line insertion and extraction test Connector single port insertion and extraction test Connector insertion and extraction duration test Connector single pin and plastic retention test Connector normal force test Connector clip compression test Connector dynamic impedance test Various tensile and pressure test Connector dynamic impedance test (optional)